top of page

PRODUCTS WE DELEIVER 

3fa0181a3bff18d9bb9064b8c5d33c6a.jpg

Tapered Columns

PRIMARY FRAMING

Primary Members:

The Main Frames (Primary Members) are the main support members made from high strength steel (345 mpa) that carry the main load of the Pre-Engineered Building.  PEB primary members consists of tapered columns, tapered rafters, beams and joists etc. These main frames are fabricated using steel structure manufacturing standards.

Columns (2).jpg

Tapered Columns

Tapered Column

empty-steel-structure-building.jpg

Straight Columns | Crane Brackets | Crane Beams

Rafters_edited.jpg
2Easy-Assembled-Peb-Steel-Structure-with

Rafters

Mezzanine Beams and Joists

SECONDARY FRAMING

z Purlin.png
purlin-3_edited.jpg
Z Purlin.jpg

Z PURLIN

72aaa206-c903-405b-a63a-00958e3395ef.jpg

C PURLIN

Purlins, Girts and Eave Struts are secondary structural members used to support the wall and roof panels. Purlins are used on the roof; Girts are used on the walls and Eave Struts are used at the intersection of the sidewall and the roof. Its commonly varies from 180 mm to 300 mm wide and 1.5 mm to 2mm thick.

C Purlin.jpg

C PURLIN

BRACINGS

Bracings are used in the roofs and walls of buildings to transfer lateral loads like wind forces, earthquake load to the building substructure. pipes, solid smooth rods, angles are the standard bracing system commonly used.

d35bad340a81a8026bcf300a9e7c1cda_edited.

ANGLE BRACING

p-erection-4-1.jpg

PIPE BRACING

linerpanel2_edited.jpg

ROD BRACING

Flange Angle Bracing.jpg

FLANGE BRACING

E58513_o0fpfb_edited.jpg

PORTAL BRACING

ROOF & WALL SHEET PANELS

Trapezoidal profiled Sheets/Panels used for sheeting purpose are generally of high ribbed steel sheets used as roof and wall sheeting, roof and wall liners, partition etc. These sheets are generally produced from steel coils having thickness 0.47 mm to 0.8 mm high yield strength i.e 550mpa.

Bare Galvalume Sheet for Roof.jpg

BARE SHEET FOR ROOF

color coated-profile sheet for wall.jpg

COLOR COATED SHEET FOR WALL CLADDING

PUFF PANELS

PUFF PANEL IS Metal-faced polyurethane sandwich panels are the system of choice of today for large industrial buildings refrigerated warehouses,office blocks,exhibition halls,fair pavilions,schools and sports halls.

​

The aluminium or steel facings themselves are surface coated and can be manufactured with profiles of various depths leading to a higher load bearing.

Polyurethane sandwich panels come complete with specially formed tongue-and -groove joints ensuring a perfect fit and maximum integrity,Assembly is fast,easy and cost effective.

​

The resultant sandwich panel has a load-bearing capability many times greater than the achieved by adding together the load-bearing capacities of the individual layers.As a result these thin,relatively lightweight sandwich panels can safely bridge wide spans. For Example,a panel just 100mm thick can easily bridge a clear span of some meters.

Puff Panels.jpg
pu-pir-puf-panels.png

FLASHINGS/TRIMS

50522c7f-d4f8-4025-a825-88c64ead05f4.jpg

Metal roof flashings are made up of metal strips that are mostly bends screwed to both the roof and the walls for closures of building, drainage of rain water and it also gives aesthetic look to a pre engineering building.

27396.jpg

POLYCARBONATE/SKYLIGHT 

It is also called skylight commonly used to bring natural light inside the building through roof and walls which reduce the power consumption also

corrugated polycarbonate sheet.jpg
395247-314885-BlueScope_Building.jpg

High strength Self-Drilling screws and bolts are the primary methods of holding the members of Pre-engineered buildings(PEB) construction together. There are a variety of screws, nuts, and bolts that are available for construction purposes, and they play an essential role in the PEB industry.

Fasteners

0010664_painted-sheet-metal-screws-10-x-

Color Coated Screws

IMG20200711163334-removebg-preview_edite

HR Hardware

high strength friction grip bolts.jpg

HR Hardware

Decksheet

A Composite Decking Sheet is constituted by a profiled sheet made of metal onto which a layer of concrete is poured. The GI decking sheet is attached to the concrete by method for mouldings on the sheet which prevent the cement from slipping on a level plane and disconnecting vertically.  At the point when the concrete is spilled and until it has arrived at a proper level of solidifying, the weights of the concrete, staff working and supplies utilized as a part of borne by the sheet alone. When the cement has solidified the sheet and the concrete structure a bound together bond.

China-Design-and-Manufacture-Steel-Struc
decking-sheet-500x500.jpg

Thermal Insulation

Thermal insulation is used in reduction of heat transfer inside the metal building through roof and walls.

 

 There are commonly two types of thermal insulation used in Pre Engineered Building

1.Bubble wrap Insulation with 4 mm,8 mm, 10mm, 12 mm thicknesses

2.Glass wool Insulation with 30 mm, 50 mm

Bubble Wrap Insulation.jpg

Bubble Wrap

durable-air-bubble-insulation-sheet-628_
Thermal-Glasswool Insulation.jpg

Glasswool

glasswool-insulation-600x362.jpg
03f5eb7c-1b58-429f-8c35-b2797599e7af.jpg

Rockwool

Jan_ROXUL-2.jpg

Ventilators

th.jpg

Roof Monitor

Ventilators are the intentional introducers of outdoor air into a space. Ventilation is mainly used to control indoor air quality by diluting and displacing indoor pollutants.

Roof Monitor.jpg
S Type Louver.jpg
S Type Louvers.jpg

S - Type Louvers

Ridge-ventilator.jpg
0007612_ridg-vent-roof-vents_600.jpeg

Ridge Vents

Turbo Ventilator.jpg
new-banne3_edited.jpg

Turbovent

Cage Ladder

photo-1517817202632-3dfdb312d6d3.jpg
65104-8823658.jpg

Cage ladder is used to access the roof for any kind of maintenance required or any other purposes like solar panels installation etc.

Anchor Bolts

80-0.jpg

Anchor bolts are used to connect structural and non-structural elements to the concrete.The connection is made by an assembling of different components such as: anchor bolts (also named fasteners), steel plates, stiffeners. Anchor bolts transfer different types of load: tension forces and shear forces. A connection between structural elements can be represented by steel column attached to reinforced concrete foundation. It varies from 16mm, 20 mm, 24mm 28 mm, 32mm diameters.

38799-20160222090414_anchor_bolt_13mm_j_
LG498928.jpg
bottom of page